Location -> Service
Type:220, 221, 222 series Coated Thickness Meter
Illustrate: Ribot coated thickness meter adopts magnetic and eddy current two methods for measurement, can be measure the thickness of non-magnetic cover layer on magnetic metallic
CX-CTG-220, 221, 222 Coated Thickness Meter
Main function:
Ribot coated thickness meter adopts magnetic and eddy current two methods for measurement, can be measure the thickness of non-magnetic cover layer on magnetic metallic coatings nondestructively(such as steel, iron, alloy and hard magnetic steel with aluminum, chromium, copper, zinc, tin, rubber, paint and so on ), and thickness of the non-conductive insulating cover layer on non-magnetic metal (such as aluminum, copper, zinc, tin, rubber, plastic, on the rubber, plastic ,oil print, oxidation film etc.).
●All English menu;
●2 types measuring method;
●2 types working method;
●Memory up to 500 ocs measurement value;
●Data delete function;
●Can set the limits;
●can automatic alarm for measurement value
of out of limits;
●Undervoltage indication of power;
●manual and automatic power off.
Technical parameter:
Main function:
Ribot coated thickness meter adopts magnetic and eddy current two methods for measurement, can be measure the thickness of non-magnetic cover layer on magnetic metallic coatings nondestructively(such as steel, iron, alloy and hard magnetic steel with aluminum, chromium, copper, zinc, tin, rubber, paint and so on ), and thickness of the non-conductive insulating cover layer on non-magnetic metal (such as aluminum, copper, zinc, tin, rubber, plastic, on the rubber, plastic ,oil print, oxidation film etc.).
●All English menu;
●2 types measuring method;
●2 types working method;
●Memory up to 500 ocs measurement value;
●Data delete function;
●Can set the limits;
●can automatic alarm for measurement value
of out of limits;
●Undervoltage indication of power;
●manual and automatic power off.
Technical parameter:
CTG-220 | CTG-221 | CTG-222 | ||||
Measuring head type | F1 | N1 | F1 or N1 | |||
Operational principle |
Magnetic induction |
Eddy current |
Magnetic induction or Eddy current |
|||
Measuring range | 0~1250μm | |||||
Lower limit resolution | 0.1μm | |||||
Accuracy | One-point Calibration | ±(3%H+1) | ||||
Two-point calibration | ±[(1~3%)H+1] | |||||
Measure condictions |
The mini. radius of curvature(mm) |
bulge 1.5、concave 9 | ||||
Mini.area dia.(mm) | Φ7 | |||||
Basic critical thickness(mm) |
0.5 | |||||
Working environment | temperature | 0~40℃ | ||||
humidity | 20%~90% | |||||
Power supply | AAA alkaline batteries 1.5V(2 pcs) | |||||
Outline dimension | 150×55.5×23mm(Main body) | |||||
Weight | F1/165g,N1/205g | |||||
standard configuration |
Main body, “AAA” alkaline batteries, standard test block, basal body |
|||||
Optional configuration | - | - | Various probe |
Last:230,231,232 series Coated Thic.. Next:210,211 series Coated Thickness..